@article { author = {Jalilian, A.R and Rowshanfarzad, P and Moafian, J and Ensaf, M.R and SAbet, M}, title = {Preparation and Quality Control of Radiolabelled Cobalt-57 Bleomycins for Oncological Studies}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {1-6}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {[55Co] bleomycin has been widely used in oncological studies. Due to relative short half life of cobalt-55, optimization and feasibility studies for determination of the best labeling conditions is preferably performed using cobalt-57. In this study, the optimization of complexation conditions for time, temperature and ligand concentration were performed. The best labeling yield was obtained at room temperature in pH of 4-7, using 0.4 mCi of 57CoCl2 with 0.3mg of BLM in 30 minutes. The final radiopharmaceutical solution underwent common quality control tests, validating our future studies for animal scanning studies using [55Co]bleomycin complex. }, keywords = {Cobalt-57,Cyclotron,Quality Control,Bleomycin,Labelled Compounds,Single Photon Emission Computed Tomography (SPECT)}, title_fa = {تهیه و کنترل کیفی ترکیبات بلئومایسین نشاندار شده با رادیوایزوتوپ کبالت-57 برای مطالعه تومورهای سرطانی}, abstract_fa = {رادیوداروی [Co55] - بلئومایسین برای مطالعه تومورهای سرطانی کاربرد گسترده‌ای یافته است. با توجه به نیمه عمر کوتاه کبالت-55، برای انجام مطالعات اولیه و بررسیهای کامل در زمینه نشاندارسازی، استفاده ازرادیوایزوتوپ کبالت-57 به مراتب مناسبتر است. مطالعات جامع به منظور تعیین بهترین دما، اسیدیته، زمان و غلظت واکنشگرها برای نشاندارسازی با کبالت-57 انجام شد. نتایج اولیه نشان دادند که بلئومایسین (به مقدار 0.3 میلی‌گرم) در محیط اسیدی ضعیف تا خنثی در دمای اتاق و در حضور کلریدکبالت (0.4  میلی‌کوری)، در محیط آبی کمپلکس تشکیل می‌دهد. کنترلهای کیفی، از جمله کنترل رادیونوکلئیدی، رادیوشیمیایی و شیمیایی روی محصولات اولیه انجام گرفت که نشان‌دهنده امکان استفاده از این ترکیب در آزمونهای زیست‌شناختی بود. این نتایج در آینده نزدیک برای تهیه ترکیب [Co55] - بلئومایسین مورد استفاده قرار خواهند گرفت تا تصویربرداری و داده‌های زیست‌شناختی از آن تهیه شود.}, keywords_fa = {کبالت-57,سیکلوترون,کنترل کیفی,بلئومایسین,ترکیبات نشاندار,برش‌نگاری محاسبه شده با گسیل تک فوتون}, url = {https://jonsat.nstri.ir/article_678.html}, eprint = {https://jonsat.nstri.ir/article_678_980ebdd9763f4c8295a19a4aa2f9a56f.pdf} } @article { author = {Raisali, Gh.R and Hamidi, S and Hallajfard, E and Shahvar, A and Hajiloo, N}, title = {Optimization of Shadow Cone Length and Mass for Determining the Amount of Scattered Radiation Dose in the Calibration Laboratory of Am/Be Neutron Source}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {7-12}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {The shadow cone technique is one of the methods which is used for determining the contribution of scattered particles on the response of neutron detectors. This technique is used for neutron field calibration in Agriculture, Medicine and Industry Research School (AMIRS). In this investigation, we have designed and constructed an optimized shadow cone. According to the calculated neutron dose equivalent attenuation factors, a cone with 20 cm of iron and 30 cm of polyethylene has been found as optimum. For this cone, the neutron dose equivalent attenuation factor for 241Am/Be neutron source, is 0.00035 for which the contribution of scattered neutrons in AMIRS neutron calibration laboratory according to the calculation and measurement results, can be evaluated with less than 0.5% of error.   }, keywords = {Shadow Cone,Optimization,Am/Be Neutron Source,Calibration,Monte Carlo Method,Attenuation Factor,Scattering}, title_fa = {بهینه‌سازی طول و جرم مخروط سایه به منظور تعیین سهم دُز پرتوهای پراکنده شده در آزمایشگاه کالیبراسیون میدان نوترون چشمة Am/Be}, abstract_fa = {تکنیک مخروط سایه یکی از روشهای برآورد سهم پرتوهای پراکنده به هنگام کاربرد آشکارساز است که به منظور کالیبره‌کردن آشکارسازهای نوترون در آزمایشگاه کالیبراسیون میدان نوترون پژوهشکده تحقیقات کشاورزی، پزشکی و صنعتی مورد استفاده قرار گرفته است. در این تحقیق، برای طراحی و ساخت یک مخروط سایه بهینه، ضریب تضعیف دْز معادل نوترون به ازای ضخامت‌های مختلف آهن و پلی‌اتیلن در میدان چشمة Am-Be241، با استفاده از کد MCNP حساب شده است؛ سپس با توجه به نتایج محاسبه، برای دستیابی به ضریب تضعیف مورد نیاز، ضخامت بهینه مخروط 50 سانتی‌متر (شامل 20 سانتی‌متر آهن و 30 سانتی‌متر پلی‌اتیلن) تعیین شده است. در این حالت ضریب تضعیف نرخ دْز معادل نوترون در میدان نوترونی چشمه Am-Be241 با حضور مخروط سایه، برابر 0.00035 است که با استفاده از این مخروط سهم نوترون‌های پراکنده شده در پاسخ آشکارساز، بر اساس نتایج اندازه‌گیری و محاسبه با خطایی کمتر از 0.5 درصد در آزمایشگاه موردنظر قابل اندازه‌گیری است.}, keywords_fa = {مخروط سایه,بهینه‌سازی,چشمة نوترون Am/Be,کالیبراسیون,روش مونت‌کارلو,ضریب تضعیف,پراکندگی}, url = {https://jonsat.nstri.ir/article_679.html}, eprint = {https://jonsat.nstri.ir/article_679_5a062158520be5c9166d50b0b41dda2f.pdf} } @article { author = {Sattari, A and Kamali Moghadam, K and Mirzaie, M and Aslani, G and Bahrami, A and Rajamand, A}, title = {Formulation of Sodium Iodide (Na 123I) Oral Capsule}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {13-17}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {I-123 is a well known radioisotope used for thyroid and its metastases studies. Nowadays this radioisotope produces from Proton bombardment of enriched Xenon 124 by Cyclotron. In this article formulation and quality of the Na 123I has been mentioned. After bombardment, the target was rinsed by distillated water and a clear and colorless acidic solution containing Iodin-123 was obtained. In order to adjust the pH value on 7 and for preparation of Na 123I, a buffer was added to the solution. The results of the quality control were according to the U.S pharmacopoeia, as well as, the high radionuclide purity of 99.99% and radiochemical purity 98%. The solution was added to the capsules that had already filled by the inert powder. Each capsule contained 200 µCi of Na123I, and was sent to be used in hospital.}, keywords = {123I,Sodium Iodide,123I Capsule,Radiopharmaceuticals}, title_fa = {فرموله کردن کپسول خوراکی ید-123}, abstract_fa = {یْد-123 یکی از رادیوایزوتوپ‌های شناخته شده در پزشکی هسته‌ای است که برای مطالعة غده تیروئید و متاستازهای آن بکار می‌رود. این رادیوایزوتوپ در سیکلوترون از بمباران گاز زینون-124 غنی شده به وسیلة پروتون تولید می‌شود. از آنجایی که یکی از موارد مصرف این رادیوایزوتوپ کپسول خوراکی یْدید سدیوم است بر آن شدیم تا با استفاده از یْد-123 تولید شده، کپسول خوراکی آن را تهیه کنیم. پس از  بمباران و شستشوی هدف، با بکارگیری بافر مناسب و تنظیم pH در محدوده 7، یْدید سدیوم (یْد- 123) تهیه شد. بررسی نتایج بدست آمده از آزمایشهای کنترل کیفیت و مقایسه آنها با فارماکوپه آمریکا، بیانگر خلوص بالای رادیوهسته‌ای 99.99%  و رادیوشیمیایی 98% این محصول بود. محصول تهیه شده به میزان 200 میکروکوری در هر کپسول بسته‌بندی و به بیمارستان ارسال شد.}, keywords_fa = {ید-123,سدیوم آیداید,کپسول ید-123,رادیوداروها}, url = {https://jonsat.nstri.ir/article_680.html}, eprint = {https://jonsat.nstri.ir/article_680_31b21c3ce300412975d93dfb1ef655d2.pdf} } @article { author = {Naderi, S and Sarraf Mamoory, R and Riahi Noori, N}, title = {Investigation of Effective Parameters in Preparation and Controlling Lithium Fluoride Nano Size Powder}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {18-24}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {In this research, the reaction of LiOH + HF   LiF+H2O has been selected and some precipitation parameters such as pH, temperature, time, super saturation, and agitation type have been studied, and controlled. The morphology, phase analysis and particle size of the resulting powders were analyzed by SEM, XRD and LPSA. Finally, at temperature 25°C, pH of about 2-3, reaction time less than 1 sec, and agitation by ultrasonic bath, the pure nano lithium fluoride powders of about 100 nm were produced.}, keywords = {Lithium Fluoride,Dosimetry,Nano Powder,Precipitation}, title_fa = {بررسی پارامترهای مؤثر در تولید و کنترل اندازة نانو پودر فلورید لیتیوم (LiF)}, abstract_fa = {در این کار پژوهشی، از میان چند واکنش شیمیایی تولید LiF، واکنش 02LiOH+HF     LiF+H انتخاب و پارامترهای رسوب دادن مانند دما، pH، زمان، فوق اشباع و همزدن مورد مطالعه قرار گرفته و کنترل شدند. پودرهای حاصل به وسیلة SEM، XRD و LPSA مورد آنالیز شکل، فاز و دانه‌بندی قرار گرفتند. در نهایت، با شرایط دمای 25 درجه سانتی‌گراد، pH حدود 3-2، زمان کمتر از 1 ثانیه و همزدن اولتراسونیک، پودر LiF با دانه‌بندی حدود 100 نانومتر و مکعبی شکل، با درجة خلوص بالا تولید شد.}, keywords_fa = {فلوئورید لیتیوم,پرتوسنجی,نانو پودر,رسوب‌دهی}, url = {https://jonsat.nstri.ir/article_681.html}, eprint = {https://jonsat.nstri.ir/article_681_85a78ce87a796fbfc506edd670499e64.pdf} } @article { author = {Zare, S and Hayatgeiby, H and Alivandy Farkhad, S and Tagizadeh, A}, title = {Effects of Extremely Low Frequency Electromagnetic Fields on Liver Enzymes in Guinea Pig}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {25-30}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Electromagnetic field has various effects on living organisms such as blood composition or enzymatic changes. The effects depend on the electromagnetic intensity and the time of exposure. This study has been carried out to measure the variations of liver enzymes SGOT and SGPT Levels in 36 adult male, Guinea Pigs, that have been divided into 6 groups. Group A, as the control, exposed to nil electromagnetic field for two hours per day for 5 days. Group B, exposed to 0.013 micro T in 5 Hz for the same period. Group C, exposed to 0.207 micro T in 50 Hz in the similar condition. Group D, exposed for four hours per day for 5 days in 0.013 micro T in 5Hz. Group E, tested in 0.207 micro T in 50 Hz as the group D. Group F, used as the controlled group exposed for four hours per day in nil electromagnetic field. Blood of the Guinea pigs were analysed after 5 days. The results have shown significant differences among different groups, regarding the SGOT and SGPT when compared with those of the controlled group. Statistically, they are meaningful when measured by Dunnett test indicating a significant difference between the controlled group and the tested group, soas the SGOT and SGPT have decreased in both cases. }, keywords = {Electromagnetic Field,Liver Enzymes,Biological Radiation Effects}, title_fa = {اثرات میدانهای الکترومغناطیسی با فرکانس بسیار پایین بر میزان آنزیم‌های کبدی در خوکچه هندی}, abstract_fa = {میدانهای الکترومغناطیسی اثرهای متفاوتی بر موجودات زنده دارند. فاکتورهای خونی و تغییرات آنزیمی از جمله این اثرها می‌باشند. این اثرها به شدت میدان الکترومغناطیسی و مدت قرارگرفتن در این میدان بستگی دارند. در این تحقیق میزان تغییر در آنزیم‌های کبدی SGPT و SGOT در 36 خوکچة هندی نر بالغ که به 6 گروه تقسیم شده بودند اندازه‌گیری شد. گروه A به عنوان گروه کنترل در میدان الکترومغناطیسی خاموش به مدت پنج روز هر روز دو ساعت، گروه B در میدانی به شدت 0.013  میکروتسلا با فرکانس 5 هرتز در همین مدت، گروه C ‌در میدانی به شدت 0.207  میکروتسلا با فرکانس 50 هرتز در شرایط زمانی مشابه، گروه D چهار ساعت در روز برای پنج روز در میدانی به شدت 0.013  میکروتسلا با فرکانس 5 هرتز، گروه E ‌در میدانی به شدت 0.207  میکروتسلا با فرکانس 50 هرتز مشابه شرایط زمانی گروه D ، و گروه F‌ به عنوان گروه کنترل، چهار ساعت در روز به مدت پنج روز در میدان خاموش قرار گرفتند. خون خوکچه‌های هندی بعد از پنج روز آزمایش شد و آنالیز داده‌ها با تست تشخیصی دانت و واریانس یک طرفه نشان داد تفاوت معنی‌داری بین گروه کنترل و گروه آزمایش وجود دارد به طوری که SGOT و SGPT در هر دو کاهش یافته بودند.}, keywords_fa = {میدان الکترومغناطیس,آنزیم کبدی,تأثیرات بیولوژیکی تابش}, url = {https://jonsat.nstri.ir/article_682.html}, eprint = {https://jonsat.nstri.ir/article_682_47ce48735d09fdade8dee6753b3a805a.pdf} } @article { author = {Ghorbanzadeh Mashkani, S and Tajer Mohammad Ghazvini, P and Ghafourian, H and Ahmadi, M.A}, title = {Biosorption of Rhenium by New Strain of Bacillus sp. MGG-83}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {31-35}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {One of the most important application of rhenium is its use in nuclear medicine.The recovery of rhenium via biosorption by micro-organisms, in contrast to other methods, has not been investigated yet. In the present study the biosorption of rhenium on Bacillus sp. MGG-83 in a batch of stirred system is reported, and its optimum condition has been determined. The optimum pH-value of the medium was found to be 2 for rhenium. The maximum biosorption of rhenium was obtained at a temperature between 35–40 0C. The rhenium take up increases by increasing the rhenium concentration, and for 250 mg/l the take up was 146.3 mg/g dry wt. The uptake of rhenium within 5 min of incubation is relatively rapid and the continuation of absorption behaves slowly thereafter. The reduction in the V/X0value causes an increase of the adsorbed rhenium and that is due to the increase of the adsorption surface area. The desorption of rhenium which has been carried out with 0.1 M sodium hydroxide at 25 0C was 55%. }, keywords = {Bacillus,Absorption,Bioadsorbents,Sorptive Properties,Rhenium,Microorganisms,Desorption,Bacillus sp. MGG-83}, title_fa = {جذب زیستی رنیوم توسط سویه جدید Bacillus sp. MGG-83}, abstract_fa = {کاربرد Re-188 و Re-186 در پزشکی هسته‌ای به منظور درمان سرطان از سال 2000 به بعد اهمیت بسیار زیادی یافته است. بررسی‌ها نشان داده است که برخلاف فلزات دیگر تاکنون هیچ گزارش علمی دربارة جداسازی رنیوم به وسیلة جذب زیستی، در مراجع معتبر علمی مشاهده نشده است. در این کار پژوهشی توان جذب رنیوم توسط باکتری جدید Bacillus sp. MGG-83، به طور مداوم در اِرلن مورد بررسی قرار گرفت و شرایط بهینة جذب مشخص شد. در بررسی اثر pH مشخص شد که pH بهینه جذب برای رنیوم برابر با 2 بوده و دمای بهینه جذب، ºC40-35 بدست آمد. جذب رنیوم با افزایش غلظت آن در محیط افزایش یافت، بطوریکه در غلظت 250 میلی‌گرم برلیتر مقدار جذب برابر با 146.3  میلی‌گرم برای هر گرم وزن خشک باکتری بود. جذب رنیوم در 5 دقیقه اول مجاورت، سریع بود و در ادامة جذب، روند کندی از خود نشان داد. کاهش در مقدار V/X0 باعث افزایش جذب رنیوم شد که این پدیده به علت افزایش محل‌های سطحی اتصال است. در بررسی استفاده از اثر عوامل رهاساز، مشخص گردید دفع رنیوم که توسط محلول 0.1  مولار هیدروکسید سدیوم در دمای ºC25 صورت گرفت، 55% رنیوم جذب شده از توده سلولی رها شد.}, keywords_fa = {باسیـل‌هـا,جـذب,جـذب‌کننـده‌هـای زیستـی,خـواص جـذبـی,رنیـوم,ریـزسـازواره‌هـا,دفـع,Bacillus sp. MGG-83}, url = {https://jonsat.nstri.ir/article_683.html}, eprint = {https://jonsat.nstri.ir/article_683_49f7024cd1192e0cc6a6919835ab694c.pdf} } @article { author = {Kashian, S and Rahighi, J and Azizi Shamami, M and Ghods, H}, title = {Measurement of 14.8 MeV Neutron Flux of a Neutron Generator Using Neutron Activation Technique}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {36-41}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Fast neutron flux (14.8 MeV) of a neutron generator has been measured by activation technique. The measurements performed using Cu and Ni threshold detectors. 62Cu and 57Ni were produced through 63Cu (n, 2n) 62Cu and 58Ni (n, 2n)57Ni reactions. They decay by emitting 511 keV and 1377 keV gamma rays, respectively. The half life of 62Cu is 9.74min and that of 57 Ni is 36 hours. The flux of neutron has been calculated by measuring the activity after the irradiation time. Gamma spectroscopy of the activated foils was performed using a HPGe detector. By employing this technique the neutron flux of 2.64×107±3%n/s was obtained for 60 μΑ deuteron of 110 keV energy, bombarding a solid target of 3H. }, keywords = {Neutron Generator,Neutron Flux,Threshold Detectors}, title_fa = {اندازه‌گیری شار نوترون MeV 8/14 در یک دستگاه مولد نوترون با استفاده از روش فعال‌سازی با نوترون}, abstract_fa = {اندازه‌گیری شار نوترون، با روش فعال‌سازی با نوترون بوسیلة پولکهای مس و نیکل انجام گرفته است. با پرتودهی پولک مس و نیکل، ایزوتوپ‌های Cu62، Ni57 از طریق دو واکنش Cu62 (n,2n)2Cu63، Ni57 (n,2n)2Ni58 به ترتیب با نیمه‌عمرهای 9.74 دقیقه و ٣٦ ساعت تولید می‌شوند. انرژی پرتوهای گامای ساطع شده در این واکنشها بترتیب keV٥١١ و keV١٣٧٧ است. با اندازه‌گیری میزان آکتیویته هر پولک در مـدت پـرتـودهـی، شـار نـوتـرون حساب شـده است. ایـن شـار از واکنش D-T و بـا جـریـان دوتـرون μΑ٦٠ بـا استفاده از پولک مس، بـرابـر 2.64×107±3%n/s  بر روی هدف بدست آمد.}, keywords_fa = {مولد نوترون,شار نوترون,آشکارسازهای آستانه‌ای}, url = {https://jonsat.nstri.ir/article_684.html}, eprint = {https://jonsat.nstri.ir/article_684_8268c2e6c1c9e7be2321336f9d93f938.pdf} } @article { author = {Ahari Hashemi, F and Fatoorehchian, S}, title = {Consideration and Study of Indirect Method for Determination of the Percentage of Porosity with Utilizing Variety of Densities in the Structure of Graphite}, journal = {Journal of Nuclear Science and Technology (JONSAT)}, volume = {26}, number = {3}, pages = {42-48}, year = {2006}, publisher = {Nuclear Science and Technology Research Institute}, issn = {1735-1871}, eissn = {2676-5861}, doi = {}, abstract = {Density has an important role in determining the variation limit of the physical properties of graphite. The density of the graphite is inversely proportional to its porosity. The porosity is produced in the structure of graphite due to the escape of volatile from the raw materials through thermal treatment during the fabrication process. There are direct and indirect methods for the measurement of porosity in the structure of graphite. Mercury and gas porosimetry are considered as direct methods, whereas the indirect method is based on bulk and picnometry density measurements. In this research work, by the use of  different types of density, the pore production in the fabricated graphite has been determined.}, keywords = {graphite,Porosity,Density,Mercury Porosimetry,Gas Porosimetry}, title_fa = {بررسی و مطالعه روش غیرمستقیم تعیین درصد تخلخل با استفاده از انواع چگالی‌ها در ساختار گرافیت}, abstract_fa = {چگالی عامل مهمی در تعیین محدوده تغییرات خواص فیزیکی گرافیت است. تخلخل در گرافیت، چگالی قطعات آن را تحت تأثیر قرار داده و از نظر ریاضی رابطه معکوس بین تخلخل و چگالی وجود دارد. تخلخل یا بطور ذاتی در ساختار مواد خام اولیه وجود دارد و یا حاصل خروج مواد فرار از این قطعات در حین فرایندهای عملیات حرارتی تولید گرافیت است. استفاده از دستگاههایی مانند تخلخل‌سنج گازی و جیوه ای به عنوان روشهای مستقیم، در مقابل محاسبه از طریق اندازه‌گیری چگالی حجمی و پیکنومتری به عنوان روشهای غیرمستقیم جهت تعیین درصد تخلخل شناخته می شوند. در این تحقیق با استفاده از اندازه‌گیری انواع چگالی، تخلخل در قطعات گرافیت ساخته شده در پروژه مورد بررسی و ارزیابی قرار گرفته‌اند.}, keywords_fa = {گرافیت,تخلخل,چگالی,تخلخل‌سنج جیوه‌ای,تخلخل‌سنج گازی}, url = {https://jonsat.nstri.ir/article_685.html}, eprint = {https://jonsat.nstri.ir/article_685_20a0b54a5e7ca956f1a5d2073b12df9c.pdf} }