پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Design and Fabrication of the Helmholtz Coil for the Permanent Magnet Measurementطراحی و ساخت پیچهی هلمهولتز به منظور اندازهگیری آهنرباهای دائمی111131FAعلیرمضانی مقدمپژوهشکده ی فیزیک و شتابگرها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،محمدلامعیپژوهشکدهی فیزیک و شتابگرها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایرانجوادرحیقیپژوهشگاه دانشهای بنیادی، چشمهی نور ایرانJournal Article20150910The direction and magnitude of the magnetization of a permanent magnet has some deviation from the desired value after the manufacturing. This paper describes the physical and mechanical designs and finally the manufacturing process of a the Helmholtz coil for the first time in Iran in order to measure the permanent magnets magnetization for using in a planar undulator. The Helmholtz coil calibration has been discussed by using a current source and Hall probe with the necessary precision. The final precision for an easy-axis magnetization measurement is 0.03%, and accuracy is 0.015%. 160 permanent magnet blocks have been measured by the Helmholtz coil. The measurement results of the magnetization components are presented and results are used in fabrication of the first undulator at the ILSF.شدت و جهت بردار مغناطش آهنرباهای دائمی بعد از ساخت، به دلایل گوناگونی، از شدت و جهت مطلوبی که حین ساخت مورد نظر بوده است اختلاف خواهند داشت. در این مقاله، مراحل طراحی فیزیکی و مکانیکی و سپس ساخت پیچهی هلمهولتز برای اندازهگیری شدت و جهت بردار مغناطش در آهنرباهای دائمی به منظور استفاده در ساخت یک آندولاتور تخت برای اولین بار در کشور ارائه شده است. کالیبراسیون پیچهی هلمهولتز با منبع جریان و پروب هال با دقت لازم بحث شده است. دقت اندازهگیری شدت بردار مغناطش در راستای محور آسایش آن در حدود 0.03%، و صحت اندازهگیری 0.015% به دست آمده است. به کمک پیچهی هلمهولتز، تعداد حدود 160 آهنربای دائمی اندازهگیری شدهاند. نتایج اندازهگیری مؤلفههای مختلف این آهنرباها ارائه، و از نتایج به دست آمده در ساخت اولین آندولاتور طرح چشمهی نور ایران استفاده شده است.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Modification of the Stability Regions in Stretched Paul Ion Trap by Damping Forceاصلاح نواحی پایداری در دام یونی کشیدهی پائول در حضور نیروی میراکننده1217132FAایمانضیائیانپژوهشکدهی فیزیک و شتابگرها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،سید محمودسادات کیاییپژوهشکدهی گداخت هستهای، پژوهشگاه علوم و فنون هستهایمزدکزبردستگروه فیزیک، دانشگاه پیام نورعلی رضاگوشهگروه فیزیک، دانشگاه پیام نورJournal Article20150927With the change of an ion trap geometrical shape, ring and end-cap electrodes, and also damping force effects, the first and second stability regions are studied in a stretched Paul ion trap. In this article, according to a new idea, we changed the trap geometry based on the change in distances between the ring electrode (2r˳) and end-cap electrodes (2z˳). For this purpose, the geometrical parameter n=(r˳/z˳)<sup>2 </sup>was introduced in our calculations. Also, for the damping effects, we entered a viscous damping factor (<em>k</em>) in the Mathieu equation. The set of differential equation governing the motion of the confined ion is considered, taking into account the effect of damping force and the ion trap geometry. The Mathieu type differential equations were solved using Runge-Kutta Verner fifth-order and sixth-order method (RKV56). Comparisons were made with the corresponding stability diagrams without considering the effects of damping force in an ideal ion trap . The numerical results showed that, for a given ion trap mode i.e., rf only mode, the damping force and the trap geometry played important roles in the relocation of the stability diagrams. The first and second stability regions in the presence of the damping force, according to trap’s geometry, are reported for the first time.با تغییر در شکل هندسی دام و تأثیر نیروی میراکننده، نواحی پایداری اول و دوم در دام چهارقطبی کشیدهی پائول، بررسی شد. در این مقاله، منظور از تغییر در شکل هندسی دام، تغییر در فواصل بین الکترود حلقه (2r<sub>0</sub>) و الکترودهای کلاهک (2z<sub>0</sub>) است. برای این هدف،پارامتر<sup>2</sup>(z<sub>0</sub>/r<sub>0</sub>)=n در محاسبات وارد شد. همچنین، تأثیر نیروی میراکننده، با وارد کردن ثابت میرایی <em>k </em>در معادلهی ماتییو بررسی شد. دستگاه معادلات دیفرانسیل حاکم بر رفتار یون درون دام چهارقطبی با توجه به آثار همزمان نیروی میراکننده و هندسهی دام، در نظر گرفته شده است. این معادلات با استفاده از روش رونگه کوتای مرتبهی 5 و مرتبهی 6 ورنر (RKV56) به دقت محاسبه، و نواحی پایداری به دست آمده با نواحی پایداری در غیاب نیروی میراکننده در دام یونی ایدهآل (r<sub>0</sub><sup>2</sup>=2z<sub>0</sub><sup>2</sup>) مقایسه شده است. نتایج به دست آمده نشان میدهند که در یک دام یونی <em>rf</em>، نیروی میرایی و شکل هندسی دام، نقش تعیین<em></em>کنندهای در جابهجایی نواحی پایداری دارند. یادآوری میشود که محاسبهی نواحی پایداری در حضور نیروی میراکننده با توجه به تغییر در فاصلهی بین الکترودهای کلاهک با این روش برای اولین بار گزارش میشود.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Design and Calibration of a Chair-Type Whole Body Counterطراحی و کالیبراسیون یک سامانهی شمارندهی کل بدن با هندسهی صندلی1823133FAحسینپوربیگیپژوهشکدهی کاربرد پرتوها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،سعدیپورعلیگروه مهندسی هستهای، دانشگاه علوم و فنآوریهای نوین، دانشگاه اصفهانمجتبیمستجابالدعواتیگروه مهندسی هستهای، دانشکدهی علوم و فنآوریهای نوین، دانشگاه اصفهانسعیدباقریگروه مهندسی هستهای، دانشکده علوم و فنآوریهای نوین، دانشگاه اصفهانJournal Article20151222A whole body counter is used for in vivo measurement of body radioactivity to access the internal exposure of radiation workers, as well as, the internal exposure of the public. The chair-type WBC is more suitable than the other geometry for rapid monitoring in radiation accidents. In this study, a transportable in vivo monitoring system with the chair-type geometry has been designed, and evaluation of the counting efficiency has been performed to calibrate the system effectively. The counter incorporates Nal (Tl) detectors (5cm dia.×5cm), housed in a collimator, and the chair is shielded using 2cm thick lead layers. For calculating the seat angle of the chair and collimator angle, a Bottle Mannkin Absorber (BOMAB) phantom model has been used. The counting efficiencies have been obtained by using Monte Carlo simulation and from the conventional calibration experiment. For the calibration experiment, a torso phantom containing a point source is used. The minimum detectable activity (MDA) for <sup>137</sup>Cs for 10min counting interval is 448±47 Bq. The results indicate that the calibration of the whole body counter by the MCNPX code can be substituted for the actual calibration. It is shown that, the Monte Carlo simulation is an inexpensive alternative method to obtain the counting efficiency of the chair type WBC for design and accurate calibration purposes.شمارندههای کل بدن برای اندازهگیریهای مستقیم پرتوزایی بدن و ارزیابی پرتوگیری داخلی برای پرتوکاران و دیگر افراد جامعه استفاده میشوند. شمارندهی با هندسهی صندلی نسبت به دیگر هندسهها برای پایش سریع در حوادث پرتوی، مناسبتر است. در این پژوهش، سیستم پایش قابل حملی با هندسهی صندلی، طراحی شد و ارزیابی بازدهی شمارش برای کالیبراسیون سیستم انجام گرفت. این سامانه از یک آشکارساز سوسوزن یدور سدیم (قطر cm5×cm5) قرار گرفته داخل یک موازیساز، و یک صندلی که با لایههای سربی به ضخامت<br /> 2cm حفاظت شدهاند، تشکیل شده است. برای محاسبهی زاویهی صندلی و زاویهی موازیساز، از مدل فانتوم بومَب استفاده شده است. بازده شمارشها از راه شبیهسازی مونتهکارلو و آزمایشهای کالیبراسیون معمول و با استفاده از یک فانتوم نیمتنهی حاوی چشمهی نقطهای به دست آمد. کمینهی سطح پرتوزایی قابل اندازهگیری (MDA) برای چشمهی Cs<sup>137</sup> در محدودهی زمانی min 10، برابر با Bq 47±448 بود. نتایج حاکی از آن است که کالیبراسیون شمارندهی کل بدن با کد MCNPX میتواند جایگزین کالیبراسیون واقعی شود. همچنین نشان داده شد که شبیهسازی مونتهکارلو، یک روش ارزانقیمت برای به دست آوردن بازدهی شمارندهی کل بدن از نوع صندلی برای مقاصد طراحی و کالیبراسیون است.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219A Study on the Effect of Gamma Rays on Reducing the Burden of Some Pathogens in Sewage Sludgeمطالعهی تأثیر پرتو گاما بر کاهش بار برخی عوامل بیماریزای موجود در لجن فاضلاب شهری2433134FAرامسینابت عیشوپژوهشکدهی کاربرد پرتوها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،خدیجهقطبی کهنپژوهشکدهی کاربرد پرتوها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایرانفرحنازنبردیپژوهشکدهی کاربرد پرتوها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایرانرویارفیعیپژوهشکدهی کاربرد پرتوها، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایرانJournal Article20150606<strong>:</strong> The reuse of sludge in agriculture leads to the transfer of some pollutants into food chain, thus hazarding the public health. The pathogens, heavy metals and nutrients in the sewage sludge from two wastewater treatment plants in Tehran-Iran, Shahid Mahallati and Ekbatan, were investigated in three independent samplings. Moreover, the reduction of pathogens after irradiation by 10kGy gamma ray from <sup>60</sup>Co was studied. The obtained results indicated that the heavy metals and nutrients in both of the wastewater treatment plants comply with Environmental Pollution Agency Standards and the pathogens counts reduced to the extent of the permitted level after irradiation. Viable Ascaris eggs in Ekbatan sludge was more than permitted level even after irradiation. According to the obtained data, just the sewage sludge of Shahid Mahallati treatment plant produced class A biosolids by irradiation which means that it can be applied to the agricultural lands, public contact sites and even home gardens. The odor of irradiated samples reduced as compared with the control ones. Vector attraction reduction processes must be conducted before use. The capability of the mentioned dose of gamma ray in converting the municipal sewage sludge into a sanitary fertilizer, depends on the microbial contamination level, specially the numbers of viable Ascaris eggs.استفاده از لجن فاضلاب در کشاورزی، باعث انتقال آلایندهها به زنجیرهی غذایی و انتشار آنها میشود. در این مقاله، میزان عوامل <br /> بیماریزا و نیز فلزهای سنگین و مغذی در لجن حاصل از فاضلاب تصفیهخانههای شهری اکباتان و شهید محلاتی (تهران) در سه نوبت نمونهبرداری مستقل بررسی شد. همچنین کاهش عوامل بیماریزا در لجن به دست آمده با دز kGy10پرتو گاما حاصل از Co<sup>60</sup> مطالعه شد. نتایج نشان داد که لجن تصفیهخانهها از نظر مقدار فلزهای سنگین و مغذی در محدودهی مجاز استاندارد است. بوی نمونههای پرتودیده کمتر از نمونههای شاهد بود. میزان عوامل بیماریزا پس از تابشدهی به زیر حد مجاز رسید، در حالیکه تعداد تخمهای زندهی آسکاریس در لجن تصفیهخانه اکباتان حتی پس از تابشدهی، بالاتر از حد مجاز بود. با توجه به این نتایج، فقط لجن تصفیهخانهی شهید محلاتی به لجن کلاس A تبدیل شد، به این معنی که بتواند در<br /> باغها و حتی منازل قابل استفاده باشد. ضروری است قبل از استفاده از این لجن، الزامات کاهش تجمع حشرات به کار گرفته شود. قابلیت به کارگیری دز مزبور به منظور تبدیل لجن به کود بهداشتی، به دلیل ثابت نبودن آلودگی میکروبی، منوط به تعیین آلودگی اولیه است.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Measurement of the Cadmium Ratio in Esfahan Heavy Water Zero Power Reactor and Comparison of the Values Obtained in Two Different Pitchesاندازهگیری نسبت کادمیم در راکتور صفر- قدرت آب سنگین اصفهان و مقایسهی مقادیر به دست آمده در دو گام مختلف3441135FAمحمدحسیناستکیگروه مهندسی پزشکی، دانشکدهی مهندسی، دانشگاه اصفهان،جمشیدخورسندیپژوهشکدهی راکتور، پژوهشگاه علوم و فنون هستهایمحمد حسیناستکیگروه مهندسی پزشکی، دانشکدهی مهندسی، دانشگاه اصفهانپروینکاویانیپژوهشکدهی راکتور، پژوهشگاه علوم و فنون هستهایJournal Article20151101 Measurement of cadmium ratio is one of the basic parameters in nuclear reactors. In this paper, the amount of cadmium ratio for the Esfahan Heavy Water Zero Power Reactor (EHWZPR) in two pitches of 18 and 20cm have been measured. For the cadmium ratio measurements Mn-Ni foils were used. The activity of the Mn-Ni foils were obtained by plastic scintillator and NaI(Tl) detectors for beta and gamma rays. Also, changes of the cadmium ratio in the axial direction of the reactor, asymptotic region or stable spectrum were obtained. The length of stable spectrum of the reactor increased to approximately 19cm, in pitch of 20 to 18, due to the reduced number of fuel rods and critical height of heavy water. To verify the measured values, the Esfahan Heavy Water Zero Power Reactor was simulated with the MCNPX-2.6.0 code. The results of simulation were in good agreement with those of the experiments. <br /> اندازهگیری نسبت کادمیم یکی از پارامترهای اساسی در راکتورهای هستهای است. در این مقاله، مقدار نسبت کادمیم برای راکتور صفر- قدرت آب سنگین اصفهان (HWZPR) در دو گام 18 وcm 20 اندازهگیری شده است. از پولکهای منگنز- نیکل برای اندازهگیری نسبت کادمیم استفاده شده است. پرتوزایی پولکها با آشکارساز سوسوزن پلاستیکی و یدور سدیم برای پرتوهای بتا و گاما به دست آمده است. همچنین از تغییرات مقدار نسبت کادمیم در راستای محوری راکتور، ناحیهی مجانبی یا طیف پایدار به دست آمده است. طیف ثابت راکتور، در گام 20، تقریباً cm19 نسبت به گام 18 افزایش یافته است، که این به دلیل کاهش تعداد میلههای سوخت و افزایش ارتفاع بحرانی آب سنگین است. برای بررسی درستی مقادیر تجربی اندازهگیری شده، راکتور صفر- قدرت آب سنگین اصفهان با کد MCNPX-2.6.0 شبیهسازی شد. نتایج حاصل از شبیهسازی و تجربی سازگاری خوبی با هم داشتند.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Development of a Qualified MELCOR Model for IR-360 NPP Using SNAP Softwareتوسعهی مدل معتبر MELCOR نیروگاه هستهای IR-360 با استفاده از نرمافزار SNAP4255136FAفرامرزیوسفپورپژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی و شرکت مسنا، سازمان انرژی اتمی،عارفالدینزرنوشه فراهانیگروه مهندسی هستهای، دانشگاه آزاد اسلامی، واحد علوم و تحقیقات تهرانمحمدرهگشایگروه مهندسی هستهای، دانشگاه آزاد اسلامی، واحد علوم و تحقیقات تهرانسیدمحسنحسینیدانشکدهی علوم پایه، دانشگاه آزاد اسلامی، واحد تهران شرقJournal Article20151101Development of a qualified thermal-hydraulics and the severe accident model of nuclear power plants (NPPs) is of crucial importance in their design, optimization and safety evaluation. This is also the first step in the safety analysis of the IR-360 NPP for which its design is domestically in process. Without an approved and “qualified" model, deterministic safety analysis (DSA) results are not reliable. In fact, the quality of the developed model should be assessed to ensure the reliability of the analysis results. This study attempts to develop a qualified MELCOR model for the IR-360 nuclear power plant in the SNAP nuclear analysis software. By selecting the appropriate nodalization of the problem and their proper connections, the most important thermo-hydraulics parameters such as pressure and temperature of the fluid, mass flow rate, direction and magnitude of the flow in the primary loop, etc are calculated. A comparison is made between the design parameters and calculated values to obtain the deviation of the model values from the design data. The calculated deviations shown to be below the acceptable limits, specified by the DSA practice including the suggestions of the International Atomic Energy Agency (IAEA). This confirms the qualification of the developed model for the safety analysis of the plant in the next steps.توسعهی مدل ترموهیدرولیکی و معتبر حادثهی شدید برای تحلیل رفتار پویای نیروگاههای هستهای در طراحی، بهینهسازی و ارزیابی ایمنی این نیروگاهها حائز اهمیت است. برای نیروگاه بومی در حال طراحی IR-360 نیز توسعهی چنین مدلی، اولین گام در تحلیل ایمنی است. آنالیزهای ایمنی قطعی (DSA) بدون اعتبارسنجی مدل مورد نظر، قابل اعتماد نیست. در واقع لازم است صحت مدل توسعه یافته ارزیابی شود تا اطمینان لازم در خصوص اعتمادپذیر بودن آنالیزهای صورت گرفته تضمین شود. این پژوهش تلاش دارد تا مدل MELCOR معتبر برای نیروگاه IR-360 را توسعه دهد. به این منظور و برای کمینه کردن خطای کاربر، از نرمافزار آنالیز هستهای SNAP استفاده شده است. با انتخاب گرهبندی مناسب مسئله در ساختار این کد، پارامترهای کلیدی از جمله فشار و دمای سیال، دبی جرمی و مانند آن، در هر حجمکنترل و مسیر جریان در نیروگاه هستهای بررسی شده است. همچنین در اینجا با <br />مقایسهی بین پارامترهای طراحی و مقادیر محاسبه شده، میزان خطای ناشی از مدلسازی به دست آمده است. انحراف و خطای محاسباتی کمتر از حدود تعیین شده در ضوابط و معیارهای قابل پذیرش آژانس بینالمللی انرژی اتمی است، که نشاندهندهی اعتبار و کیفیت مدل موردنظر به منظور انجام تجزیه و تحلیلهای بعدی است.<br /> پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Investigation of 18F and 13N Radioisotopes Production Using Cyclotron Recirculating Liquid Targetبررسی تولید رادیوایزوتوپهای 18F و 13N با استفاده از هدف مایع چرخشی سیکلوترون5662137FAمحمدمیرزاییپژوهشکدهی کشاورزی هسته ای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،زهرهعبدیگروه فیزیک، دانشکدهی علوم، دانشگاه زنجانکامرانیوسفیپژوهشکدهی کشاورزی هستهای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمیمحمدرحیمیپژوهشکدهی کشاورزی هستهای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمیطیبکاکاوندگروه فیزیک، دانشکدهی علوم، دانشگاه بینالمللی امام خمینی (ره)شهرزادفضلیگروه فیزیک، دانشکدهی علوم، دانشگاه زنجانJournal Article20150726Two radioisotopes of <sup>18</sup>F (<em>T</em><sub>1/2</sub>=109.7 min, <em>I</em><sub>β</sub><sub>+</sub>= 97%, <em>E</em><sub>β</sub><sub>+</sub>= 0.63 MeV), and <sup>13</sup>N (<em>T</em><sub>1/2</sub>=10min, <em>I</em><sub>β</sub><sub>+</sub>=100%, <em>E</em><sub>β</sub><sub>+</sub>=0.96 MeV) decay almost completely via positron emission. Due to this characteristic, these radioisotopes are used in PET (positron emission tomography) camera for detection of cancer cells. In this article, after calculating the excitation function for nuclear reactions leading to the <sup>18</sup>F,<sup> 18</sup>O (p, n)<sup> 18</sup>F, and <sup>13</sup>N, <sup>16</sup>O (p, α)<sup> 13</sup>N formation using the ALICE-91 nuclear code and by a comparison of the results with the experimental data, the best range of energy to produce with a cyclotron accelerator and the amount of heat deposited to the target material, was determined. For the waste heat removal, a miniature heat exchanger was designed and manufactured. A thermal design of the heat exchanger by the Aspen HTFS+ software was created, and its mechanical plan sheet was drawn using the SolidWorks software. After the fabrication of the heat exchanger and recirculation liquid target located at the liquid target room, <sup>13</sup>N was produced via pure water proton bombardment with 17.5 MeV energies verifying the theoretical calculations. <br /> <span style="text-decoration: underline;"><strong> (با عرض پوزش چکیده مقاله به دلیل وجود مشکلات سایت با اشکال فراوان همراه است لطفا از روی پی دی اف مطالعه فرمایید)</strong></span><br /> دو رادیوایزوتوپ <span dir="ltr"> <sup>18</sup>F (<em>T</em><sub>1/2</sub>=109.7 min, <em>I</em><sub>β</sub><sub>+</sub>= 97%, <em>E</em><sub>β</sub><sub>+</sub>= 0.63 MeV) و<span dir="ltr"> <sup>13</sup>N (<em>T</em><sub>1/2</sub>=10min, <em>I</em><sub>β</sub><sub>+</sub>=100%, <em>E</em><sub>β</sub><sub>+</sub>=0.96 MeV)، min کامل تقریباً از طریق گسیل پوزیترون واپاشی میکنند. به همین سبب، از این دو رادیوایزوتوپ به منظور مقطعنگاری گسیل پوزیترون (پی ای تی) در تشخیص سلولهای سرطانی استفاده میشود. در این مقاله، پس از محاسبهی توابع برانگیختگی برای واکنشهای هستهای منجر به <span dir="ltr"> <sup>18</sup>F,<sup> 18</sup>O (p, n)<sup> 18</sup>F, و <sup>13</sup>N, <sup>16</sup>O (p, α)<sup> 13</sup>N برای تولید با شتابدهندهی سیکلوترون و میزان حرارت سپرده شده به مایع هدف تعیین شد. برای برداشت حرارت ایجاد شدهی حاصل از پرتوی فرودی در هدف، یک مبدل حرارتی مینیاتوری طراحی و ساخته شد. طراحی حرارتی این مبدل با استفاده از نرمافزار Aspen HTFS+ انجام شد. نقشهی ساخت آن نیز با نرمافزار SolidWorks ترسیم شد. پس از ساخت مبدل حرارتی و جانمایی هدف مایع چرخشی در اتاق هدف مایع، تولید N<sup>13</sup> از راه بمباران پروتونی آب خالص با انرژی MeV17.5 به منظور صحهگذاری محاسبات نظری انجام گرف.</span></span></span>پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Production, Radiolabeling and Biodistribution of 47/46Sc-DOTMP as a Radiopharmaceuticalتولید، نشاندارسازی و بررسی توزیع بیولوژیکی رادیوداروی 47.46Sc-DOTMP6369138FAلیلامقدم بنائمپژوهشکدهی چرخهی سوخت هستهای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،علیبهرامی سامانیپژوهشکدهی چرخهی سوخت هستهای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایران،فاطمهفتحیدانشکدهی مهندسی هستهای و فیزیک، دانشگاه صنعتی امیرکبیرمجتبیشمسائی ظفرقندیدانشکدهی مهندسی هستهای و فیزیک، دانشگاه صنعتی امیرکبیرJournal Article20150723Designing ideal radiopharmaceuticals for use as the bone pain palliatives requires the utilization of a moderate or low energy β-emitters with a stable carrier molecule. In this direction, cyclic polyaminophosphonic acids are known to form thermodynamically more stable and kinetically more inert complexes with lanthanides, compared to their acyclic analogs. In this study, DOTMP as the cyclic polyaminophosphonic acid and bone-seeking ligand, and <sup>47</sup>Sc radioisotope as a low energy β-emitter with the maximum energies of 0.600MeV and 0.441MeV and the short half-life of 3.47d were considered and the therapeutic potential of the bone seeking radiopharmaceutical <sup>47</sup>Sc-DOTMP was assessed by measuring its skeletal uptake in the animal model. Because of the limited availability of <sup>47</sup>Sc, this study was performed upon using <sup>46</sup>Sc radioisotope which is chemically identical.<sup> 46</sup>Sc was produced with an activity of 2.3 (85.1 MBq) mCi by irradiation of natural <sup>45</sup>Sc<sub>2</sub>O<sub>3</sub> target at a thermal neutron flux of 3.5×10<sup>13</sup> n/cm<sup>2</sup>.s in 48h at the Tehran Research Reactor (TRR). <sup>46</sup>Sc-DOTMP was prepared in radiochemical purity of about 90% in a chelant-to-metal ratio of 60:1. The in-vitro stability of the complex was evaluated at room temperature for 48h. Then, the biodistribution studies of the complex in 5 groups of mice were carried out for 7d.برای طراحی رادیوداروهای مناسب به منظور استفاده در تسکین دردهای استخوانی، به رادیوایزوتوپهای گسیلکنندهی <sup>–</sup>β با انرژی متوسط یا کم و یک مولکول حملکننده و پایدار نیاز است. در این راستا، لیگاندهای پلیآمینوفسفونیک اسیدهای حلقوی به صورت موادی که ترکیباتی با پایداری ترمودینامیکی و مقاومت جنبشی بالاتری با فلزها نسبت به مشابه مارپیچی خود تشکیل میدهند، شناخته میشوند. در این پروژه، استفاده از 1،4،7،10- تتراآزاسیکلودودکان-1،4،7،10- تترامتیلن فسفونیک اسید (DOTMP) به شکل یک لیگاند پلیآمینوفسفونیک اسید حلقوی و استخوانخواه، و رادیوایزوتوپ <sup>47</sup>Sc در نقش یک گسیلندهی کمانرژی <sup>–</sup>β با انرژیهای بیشینه MeV0.006 و MeV0.441 و نیمهعمری برابر با d3.4 در نظر گرفته شد. پتانسیل درمانی این رادیوداروی استخوانخواه از راه نشاندارسازی 1،4،7،10- تتراآزاسیکلودودکان-1،4،7،10- تترامتیلن فسفونیک اسید (DOTMP) با <sup>47</sup>Sc و اندازهگیری مقدار جذب اسکلتی آن در مدل حیوانی ارزیابی شد. به دلیل محدودیت دسترسی به رادیوایزوتوپ <sup>46</sup>Sc، این پروژه با استفاده از رادیوایزوتوپ <sup>46</sup>Sc که دارای خواص شیمیایی مشابه است، انجام شد. <sup>46</sup>Sc با پرتوزایی در حدود MBq 85.1 (mCi2.3) و بمباران اکسید Sc طبیعی به مدت زمان h48 تحت شار نوترونی .<br /> 10<sup>13</sup>*3.5 n/cm<sup>2</sup>.s در راکتور تحقیقاتی تهران، تولید شد. رادیوداروی <sup>46</sup>Sc-DOTMP با خلوص رادیوشیمیایی بالاتر از 95% و نسبت لیگاند به فلز 1:60 تهیه، و پایداری آزمایشگاهی آن به مدت h48 و در دمای اتاق ارزیابی، و سپس توزیع بیولوژیکی آن در موشها تا 7 روز بررسی شد.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Solid Phase Extraction of Thorium (IV) and Uranium (VI) from Nitrate Medium Using Cyanex 302-Coated Magnetic Nanoparticlesاستخراج فاز جامد توریم (IV) و اورانیم (VI) از محیط نیتراتی با نانوذرات مغناطیسی اصلاح شده با سیانکس 3027076139FAسعیدعلمدار میلانیپژوهشکدهی چرخهی سوخت هستهای، پژوهشگاه علوم و فنون هستهای، سازمان انرژی اتمی ایرانJournal Article20151231Magnetic nanoparticles modifdied with Cyanex 302 were used for the separation and preconcentration of Th(IV) and U(VI) from synthetic nitrate solutions. The capacity of magnetic nanoparticles (≈10 nm) coated with Cyanex 302 for simultaneous separation and preconcentration of thorium and uranium from the nitratemedium was studied by means of the batch method. The effects of analytical parameters, including the amount of Cyanex 302, pH, and initial metal concentration on the extractive behavior of metal ions were systematically studied. The results showed that the optimum weight ratio of Cyanex 302 to magnetite nanoparticles was 10% and the optimum pH of solution for the simultaneous extraction of Th(IV) and U(VI) was equal to 6. The maximal capacity of the magnetite nanoparticles modifdied with 10w% Cyanex 302 was found to be 60 mg l<sup>-1</sup> of thorium and uranium. The influences of the fission products [Cs(I), Sr(II)] and interfering ions, including Fe(III), Cr(III), Mg(II), Mn(II) and Al(III) were also investigatedبا استفاده از نانوذرات مغناطیسی اصلاح شده با سیانکس 302، یک جاذب مغناطیسی برای استخراج یونهای توریم و اورانیم از محیطهای نیتراتی ساختگی فراهم شد. توانایی و قابلیت نانوذرات مغناطیسی (10nm≈) پوشش داده شده با سیانکس 302 برای استخراج و پیشتغلیظ همزمان توریم و اورانیم از محیط نیتراتی در روش ناپیوسته ارزیابی شد. اثر مقدار لیگاند، pH محیط، و غلظت اولیهی محلول یونهای فلزی بر رفتار استخراجی یونهای توریم و اورانیم بررسی شد. دادههای آزمایشگاهی حاکی از آن است که نسبت وزنی بهینهی سیانکس 302 به نانوذرات مغناطیسی، 10% وزنی، و مقدار pH بهینهی محلول برای استخراج همزمان یونهای توریم و اورانیم برابر با 6 است. این مقدار سیانکس قابلیت جذب 60 mg/Iیون توریم و اورانیم را دارد. تأثیر حضور محصولات شکافت [(I)Sr(II),Cs] و یونهای مزاحم از جمله (III)Mn(II),Mg(II),Cr (III),Fe و (III)Al نیز بررسی شد.پژوهشگاه علوم و فنون هستهایمجله علوم و فنون هسته ای1735-187137420170219Study of High Energy Electron Beam Irradiation Dose Effects on Physical and Thermal Properties of PVA-Based Hydrogelsمطالعهی آثار دز تابشدهی باریکهی الکترونی انرژی بالا بر خواص فیزیکی و حرارتی هیدروژلها بر پایهی پلی وینیل الکل7785140FAمهدیانتظامگروه مهندسی شیمی- پلیمر، پردیس فنی و مهندسی، دانشگاه یزد،حانیهدانشیاندانشکدهی مهندسی نساجی و پلیمر، دانشگاه آزاد اسلامی، واحد یزدمحمدرضاپارسائیانمجتمع پژوهشی ایران مرکزی، پژوهشگاه علوم و فنون هستهایونوساحمدیانمجتمع پژوهشی ایران مرکزی، پژوهشگاه علوم و فنون هستهایJournal Article20151101Polyvinyl alcohol (PVA) with the desired bio-properties and relatively low cost has attracted special interest to make hydrogels, especially with the wound dressing application. On the one hand, irradiation is an appropriate method to prepare hydrogels based on PVA. In this method, the irradiation conditions, especially the irradiation dose, influence significantly the physical properties and therefore affect the performance of the hydrogel. The main objective of this research was to investigate the effect of electron beam irradiation dose on the physical and thermal (crystallinity) properties of PVA hydrogels. The hydrogels were prepared by irradiation of the aqueous solution of PVA (7 wt.%) at different doses. The gel content, equilibrium swelling degree and dehydration behavior of the hydrogels were evaluated. The chemical structure changes of the PVA due to irradiation and thermal behavior of the dried PVA gels were probed respectively by FTIR and DCS experiments. In the wake of increasing the dose, the gel content of the hydrogel increased marginally, while its swelling decreased significantly. There was no obvious effect on the hydrogel dehydration by changing in the dose. The FTIR results showed that besides the crosslinking, the PVA chains degradation was also augmented with the dose. According to the DSC results, increasing the dose caused reduction of the crystallization and melt temperatures of the PVA and increment of its crystallinity.پلیوینیل الکل (PVA) با خواص زیستی مناسب و قیمت نسبتاً ارزان، توجه ویژهای را در ساخت هیدروژلها، به ویژه با کاربرد پانسمان زخم، به خود اختصاص داده است. از طرفی تابشدهی، روشی مطلوب برای تهیهی هیدروژلها بر پایهی PVA به شمار میآید. در این روش، شرایط تابشدهی، به ویژه دز تابشدهی، بر خواص فیزیکی و در نتیجه کارایی هیدروژل بسیار مؤثر است. هدف از انجام این پژوهش، بررسی اثر دز تابشدهی الکترونی بر خواص فیزیکی و حرارتی (بلورینگی) هیدروژلهای PVA بود. هیدروژلها با تابشدهی محلول آبی PVA (wt 7%)، تحت دزهای مختلف تهیه شدند. میزان ژل، درجهی تورم تعادلی و رفتار دهیدراسیون هیدروژلها ارزیابی شدند. تغییرات شیمیایی ساختار PVA ناشی از تابشدهی با آزمون FTIR، و رفتار حرارتی ژلهای خشک PVA با آزمون DSC بررسی شدند. با افزایش دز تابشدهی، میزان ژل هیدروژل افزایش اندکی نشان داد، در حالی که میزان تورم آن با کاهش چشمگیری همراه بود. دز تابشدهی اثر قابلتوجهی بر دهیدراسیون هیدروژل نداشت. نتایج آزمون FTIR نشان دادند که علاوه بر شبکهای شدن، تخریب زنجیرههای PVA نیز با افزایش دز تابشدهی شدت میگیرد. براساس نتایج آزمون DSC، افزایش دز تابشدهی موجب کاهش دماهای بلورینگی و ذوب PVA، و البته افزایش میزان بلورینگی آن شد.